1.Date of occurrence of the event:2011/12/17
2.Company name: Ri-Teng Computer Accessory (Shanghai) Co. Ltd.
3.Relationship to the Company (please enter ˇ¨head officeˇ¨ or
ˇ¨affiliate companyˇ¨): Affiliate Company
4.Reciprocal shareholding ratios: 100%
5.Cause of occurrence:
A minor explosion occurred at particle collecting equipments in Ri-Teng
at 3pm on December 17th, 2011 and resulted in the damage to small part of
automation equipment. While the cause of explosion is under investigation,
employees who suffered injury on the site have been kept at the hospital
for observation.
6.Countermeasures:
6.1 The Company will make the best effort to provide medical treatment and
assistance to the injured employees.
6.2 The automation equipment damaged by the explosion can be tuned and
be used again for production after adjustment. Minimal impact is expected
for production and business operation.
7.Any other matters that need to be specified: None. |